Open X_T files in your browser (3D viewer, beta)
Open Parasolid transmit files (.x_t / .x_b, .xmt_txt / .xmt_bin) in your browser without installing NX, SOLIDWORKS or Solid Edge (beta). The B-rep in the file is shown with its exact surfaces, assemblies are placed as saved, and part names and colours come from the file's attributes. The STEP you hand to your CAD keeps the exact surfaces (no triangles). Viewing is free with no signup (up to 50MB per file); saving STL or OBJ needs a free account.
Supported formatsImages: AI recognition (beta)Can't upload? Desktop edition (planned)
Can't open a X_T file? Common causes and fixes
An .x_t arrived from someone who uses NX, SOLIDWORKS or Solid Edge, and you have none of them
Drop the .x_t / .x_b on this page to view it in 3D: front, top and right views, orthographic projection and the overall size in millimetres, then export a STEP for your own CAD.
The result says the Parasolid version has not been qualified
parasolid-kit reads the reviewed Parasolid versions 9 through 37 (schema keys checked against public files from NX, SOLIDWORKS, Solid Edge, Onshape, Inventor, MicroStation and IronCAD). The error names the CAD and Parasolid version that wrote the file. Ask the sender for a STEP, or submit the file so the version can be added.
Some faces are missing
Faces that cannot be built are dropped one by one and the body is shown as an open shell; the loss report counts them with the reason. Ask the sender for a STEP when the exact shape matters.
The file ends in .x_t but is reported as not a Parasolid file
Parasolid files start with the **ABCDEFGHIJKLMNOPQRSTUVWXYZ... signature line, which is checked before reading; a renamed file of another format or a truncated file cannot be read.
Ways to open a received .x_t: the CAD that wrote it, JT2Go, or a browser viewer
X_T (a Parasolid transmit file, text) and X_B (its binary form) are what CAD systems built on Siemens' Parasolid kernel (NX, SOLIDWORKS, Solid Edge, Onshape, Inventor and others) write to exchange 3D models, and they carry the exact surfaces (B-rep). Opening one needed a CAD on the same kernel or Siemens' free JT2Go on Windows. zumen-gate shows .x_t / .x_b in your browser without Parasolid (beta) and writes STL, OBJ or GLB (free) or STEP (pass or Pro); the STEP keeps the exact B-rep rather than triangles, with part names and colours from the file's attributes.
| zumen-gate (this page) | JT2Go (Siemens) | NX or SOLIDWORKS | |
|---|---|---|---|
| Installation | None (browser) | Required (Windows, free) | Required, plus a licence |
| What is read | The exact B-rep, assembly placements, part names and colours | Geometry, measuring, sections | The original model (editable) |
| Export | STL, OBJ, GLB (free), STEP (pass or Pro) | None (view and measure only) | STEP, IGES and more |
| Best for | A quick check of an incoming .x_t, a STEP to hand to your CAD | Measuring and markup on Windows | Editing |
What is covered for X_T
- Read (beta): Parasolid transmit files (.x_t / .xmt_txt text, .x_b / .xmt_bin binary) written by NX, SOLIDWORKS, Solid Edge, Onshape, Inventor, MicroStation, IronCAD and others in the reviewed Parasolid versions 9 through 37, read with built-in schema definitions (no Parasolid installation or schema file). The B-rep becomes exact OCCT bodies, assemblies (ASSEMBLY / INSTANCE) are placed as saved, and part names and colours come from the SDL/TYSA_NAME and SDL/TYSA_COLOUR attributes
- Faces that cannot be built are dropped and the body is shown as an open shell, with the counts and reasons in the loss report; negative (subtracted) instances are placed like positive ones. Files of a Parasolid version that has not been reviewed are refused, naming the writing CAD and version (to extend support, please consider submitting the failing file). Lengths are stored in metres and converted to millimetres
- Export (beta): STL, OBJ and GLB are free (up to 10MB); STEP (AP203 / AP214 / AP242) needs a pass or Pro and writes the B-rep as an assembly with part names and colours, so SOLIDWORKS, Inventor or Fusion can edit the faces (unlike the triangular faces from SOLIDWORKS files). Writing Parasolid (STEP to X_T) is not offered. Viewing is free up to 50MB
Export it while you're here
A displayed X_T file exports straight to STL, OBJ or GLB (free, up to 10MB; STL and OBJ with a free account) or STEP (download with a 24-hour pass or Pro) — pick the output above the convert button (beta). Projection to a 2D drawing (DXF) is planned; other 3D formats are on the 3D viewer page.
X_T viewer — frequently asked questions
Which CAD systems' X_T files are supported?
Files written in the reviewed Parasolid versions (schemas) 9 through 37, checked against public files from NX, SOLIDWORKS (2009–2026), Solid Edge, Onshape, Inventor, MicroStation and IronCAD. Other builds of a reviewed version (service packs of the same CAD release) are read with the same definitions. Unreviewed versions are refused, naming the writing CAD and version (beta).
What is the difference between X_T and X_B? What about units?
X_T is text and X_B is binary; both hold the same Parasolid B-rep (.xmt_txt and .xmt_bin are the same formats). Parasolid stores lengths in metres, so the view and the exports are converted to millimetres.
What happens to the surfaces, colours and part names in the STEP?
The surfaces stay the original B-rep (planes, cylinders, free-form surfaces), so unlike the triangular faces built from SOLIDWORKS display meshes, your CAD can edit them. Part names (the SDL/TYSA_NAME attribute), colours (SDL/TYSA_COLOUR) and the assembly placements are kept. The STEP download needs a 24-hour pass (¥480, about US$3) or Pro. Writing Parasolid (STEP to X_T) is not offered.